Products

FIRE PERFORMANCE CABLES

Type

Low smoke and fume cable

Use

Intended for applications requiring circuit integrity during a fire mainly used in fire alarm systems, sprinkler systems in schools, hospitals, cinemas and railways

Features & Benefits

• Cross-linked insulating material which is capable of operating at a temperature of 90°c.
• The conduit wiring cables are manufactured to bs 7211 whereas armoured cables are manufactured to bs 6724 or iec 60502-1 specifications.
• Low smoke and low acid gas fume emission in fire conditions
• Improved fire protection that reduces the risk to building occupants
• Slow to ignite, burn slowly and most importantly, emit much-reduced amounts of smoke and fumes during fire allowing people to escape.
 

Operating Temprature

90?C conductor operating temperature 

Type tested and certified by

Ducab smokemaster is certified by basec, lloyd’s register and esma.

Sizes

Wiring cables 450/750v  with xlpe/ lsf sheathing grade up to and including 630mm?2;
single core armoured cables 600/1000v with xlpe/ lsf sheathing grade up to and including 1000mm?2;
two core armoured cables 600/1000v with xlpe/ lsf sheathing grade up to and including 400mm?2;
three core armoured cables 600/1000v with xlpe/ lsf sheathing grade up to and including 400mm?2;
four core armoured cables 600/1000v with xlpe/ lsf sheathing grade up to and including 400mm?2;
multi core armoured cables 600/1000v with xlpe/ lsf sheathing grade up to and including 4mm?2;
single core armoured cables 1900/3300v with xlpe/ lsf sheathing grade up to and including 1000mm?2;
three core armoured cables 1900/3300v with xlpe/ lsf sheathing grade up to and including 400mm?2;

CONTROL & INSTRUMENTATION CABLES

Type

Control and auxiliary cables

Use

Operates small lv power supply to single or three phase a.c. loads, control circuits, processing machines, conveyors, production lines etc

Features & Benefits

• BS 5467 & IEC 60502-1 specifications and are rated 600/1000v.
• Control and auxiliary cables both armoured and unarmoured can be offered with a common/overall screen or shield. the screening material is plain annealed copper tape/copper laminate/aluminium laminate as specified

Operating Temprature

70 °C, 90 °C

Type tested and certified by

Basec, esma and lloyd’s register

Sizes

Control cable with copper conductor-xlpe/pvc insulated covering sizes 1.5 mm?2; up to 10 mm?2; in 2, 3 and 4 cores
Auxiliary cables with copper conductor xlpe/pvc insulated covering sizes 1.5 mm?2;, 2.5mm?2;, 4mm?2;  from 5 cores to 61 cores

Type

Instrumentation and pilot cables

Use

Operates small lv power supply to single or three phase a.c. loads, control circuits, processing machines, conveyors, production lines etc

Features & Benefits

Generally used within industrial manufacturing plants for control, communication, data and voice transmission signals. these cables are used typically in industrial projects and ogp industries.  they are also used to connect electrical instrument circuits and provide communication services in and around process plants with detail signal transfer.
Ducab instrumentation and pilot cables have induced voltage control. these cables are also designed for installations where interferences suppression is required

Operating Temprature

70 °C, 90 °C

Type tested and certified by

Basec, esma and lloyd’s register

Sizes

Type 1 unarmored cables – single and multi-pairs, pe/xlpe, overall screened or individual and overall screened, pvc outer sheath
type 2 armoured single and multi-pairs, pe/xlpe, overall screened or individual and overall screened, pvc outer sheath
type 3 lead sheath cables – single and multi-pairs, pe/xlpe, overall screened or individual and overall screened, lead alloy; armoured, pvc outer sheath

LOW VOLTAGE CABLES

Type

Pvc insulated wiring cables: 6491X 

Use

Electrical power, lighting and internal wiring in households, industrial and administrative buildings, agricultural premises, switchgear and distribution boards

Features & Benefits

• Have excellent thermal properties of insulation
• Pvc insulated cables provide more flexibility and less bending radius for installation.

Operating Temprature

They are used and operate at a temperature of 70°c.

Type tested and certified by

Basec, lloyd’s register and esma

Sizes

Manufactured in sizes from 1.5mm?2; to 630 mm?2; rated 450/750 v as per bs 6004.

Type

Panel wires: 6231

Use

Ducab flexible panel wires made as per BS 6231 Type CK are intended for use in the wiring of switch, control, metering, relay and instrumentation panels of power switchgear. It is also used for such purposes as internal connections in rectifier equipment and its motor starters and controllers

Features & Benefits

• BS 6231, Type CK
• Circular class 5  exible copper conductor as per BS EN 60228
• Heat Resistant PVC type TI3 as per BS EN 50363-3
• 600/1000 V
• BS EN / IEC 60332-1

Operating Temprature

-15°C to 90°C operating temperature

Type tested and certified by

BASEC, EMIRATES QUALITY MARK

Sizes

0.5mm?2; - 240mm?2;

Type

Single and multi-core flexible cables

Use

Designed for indoor wiring applications, connecting handheld equipments such as power drills, hand grinders etc where cables are subjected to stress by kinking and twisting.

Features & Benefits

• BS 6004, BS 6500, IEC 60227, bs 7919.
• Flexible conductor, class 5
• Flame non-propagation available

Operating Temprature

70 °C, 90 °C, 105 °C

Type tested and certified by

Basec

Sizes

Class 5 copper conductor, pvc insulation, sheathed/unsheathed from 0.5mm?2; to 240mm?2;.

Type

XLPE Insulated Low Voltage Cables

Use

Supply power to large motors and other industrial equipment.

Features & Benefits

• IEC 60502-1 and BS 5467 specifications for the voltage range of 600/1000v and 1900/3300v systems.
• These cables have a long service life with a defect free insulation.

Operating Temprature

90°c in continuous duty and a limiting short circuit temperature of 250°c.

Type tested and certified by

Basec, lloyd’s register and esma

Sizes

Single core armoured, unarmoured, pvc sheathed cables 600/1000v & 1900/3300v up to and including 1000 mm?2;

two core armoured, unarmoured, pvc sheathed cables 600/1000v up to and including 300mm?2;

three core armoured, unarmoured, pvc sheathed cables 600/1000v & 1900/3300v up to and including 400mm?2;

four core armoured, unarmoured, pvc sheathed cables 600/1000v up to and including 500mm?2;

four core cables with reduced neutral conductor armoured, unarmoured, pvc sheathed cables 600/1000 v  up to and including 500mm?2;

five core cables up to and including 95mm?2;

Subscription